Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
2.
Arq. bras. oftalmol ; 79(4): 264-267, July-Aug. 2016. graf
Article in English | LILACS | ID: lil-794574

ABSTRACT

ABSTRACT We report two cases of suspicious asymmetric bow tie and inferior steepening on topographic evaluations with reflection (Placido) and projection (Scheimpflug). Rotating Scheimpflug corneal and anterior segment tomography (Oculus Pentacam HR, Wetzlar, Germany)® was performed in the first case, with a maximal keratometric value (Kmax) of 43.2 D and an overall deviation value from the Belin/Ambrósio Enhanced Ectasia Display (BAD-D) of 1.76, which was observed in the study eye (OD). BAD-D was 6.59 in the fellow eye, which had clinical findings that were consistent with keratoconus stage 2. The second case presented with a Kmax of 45.3 D and BAD-D of 0.76 in OD and 1.01 in OS. This patient had discontinued wearing soft contact lens less than 1 day prior to examination. Corneal tomographic data enabled us to distinguish mild or forme fruste keratoconus from contact lens-induced corneal warpage, and similar findings were observed on curvature maps.


RESUMO O presente estudo tem por objetivo relatar dois casos suspeitos que apresentam bow tie assimétrico e encurvamento inferior nas avaliações topográficas de reflexão (Placido) e projeção (Scheimpflug). A tomografia de córnea e segmento anterior com o sistema Scheimpflug (Oculus Pentacam HR, Wetzlar, Alemanha)® mostrou no primeiro caso, a ceratometria máxima (Kmax) de 43,2 D e o valor D no Belin/Ambrósio Enhanced Ectasia Display (BAD-D) de 1,76 no olho estudado (OD). O olho contralateral apresentava BAD-D de 6,59 e achados clínicos compatíveis com ceratocone (KC) grau 2. O segundo caso apresentava Kmax de 45,3 D e BAD-D de 0,76 em OD e 1,01 em OS. Este paciente havia interrompido o uso de lentes de contato gelatinosas 1 dia antes do exame. A avaliação tomográfica avançada nos permitiu distinguir ceratocone leve ou subclínico de warpage induzido por lentes de contato, enquanto resultados semelhantes foram observados em mapas de curvatura anterior.


Subject(s)
Humans , Male , Female , Adult , Contact Lenses, Hydrophilic/adverse effects , Corneal Topography/methods , Keratoconus/pathology , Keratoconus/diagnostic imaging , Reference Values , Severity of Illness Index , Diagnosis, Differential , Dilatation, Pathologic/etiology , Keratoconus/etiology
3.
Rev. bras. oftalmol ; 74(6): 382-385, nov.-dez. 2015. tab, graf
Article in English | LILACS | ID: lil-767083

ABSTRACT

RESUMO Objetivo: Avaliar a capacidade de dados de perfil paquimétrico horizontal, a fim de distinguir o ceratocone de córneas normais, e comparar a precisão de índices com outros tomográficos mais complexos. Métodos: Em um estudo retrospectivo, um olho selecionado aleatoriamente de 225 pacientes com ceratocone bilateral e de 335 pacientes com córneas normais foram incluídos. Todos os pacientes foram examinados por um especialista em córnea e foram submetidos ao exame de tomografia de córnea, Pentacam HR (Oculus, Wetzlar, Alemanha). Os dados de perfil paquimétrico horizontal em 6 milímetros passando pelo ápice foi avaliado. Com esses dados, a espessura no ápice corneano (P.ápice), a espessura no ponto mais fino do perfil horizontal (P.min.H), a progressão paquimétrica do ponto mais fino para o mais espesso (PPmin-máx), a progressão paquimétrica média no meridiano temos como referencial a média normal (PPméd) e a adequação a uma linha de tendência polinomial do segundo grau (R2). Um modelo de inteligência artificial foi construído para combinar esses dados. O desempenho para distinguir ceratocone do normal foi avaliada por curvas ROC. Resultados: Todos os índices avaliados foram estatisticamente diferentes entre os dois grupos (p <0,001). A área sob a curva ROC (AUC) de paquimetria no ápice e no TP foram de 0,904 e 0,938, respectivamente. O índice tomográfico com maior AUC foi o BAD-D (0,997). Em relação ao perfil horizontal, a AUC do P.min.H e PPmin-max foram 0,915 e 0,927, respectivamente. A adequação à linha de tendência para o gráfico de espessura no ápice apresentou AUC 0,896. O melhor desempenho foi obtido com o PPméd (AUC 0,932 Sensibilidade = 84,4% e especificidade de 92,5%). O modelo de inteligência artificial combinando todos os itens derivados do perfil horizontal melhorou o desempenho (AUC 0,991 Sens. = 96% e espec. = 98%). Conclusão: O perfil de espessura horizontal permite detectar o ceratocone, com capacidade comparável aos índices mais complexos. Esse tipo de análise pode fornecer o básico para novas abordagens, que utilizem dados presentes em aparelhos mais simples que o tomógrafo, reduzindo o custo para os pacientes.


ABSTRACT Purpose: To evaluate the ability of horizontal thickness profile to distinguish keratoconus from normal corneas, and compare the accuracy of these indices with more complex tomographic indices. Methods: In a retrospective study, one eye randomly selected from 225 patients with bilateral keratoconus and 335 patients with normal corneas were included. All patients were examined by a corneal specialist and underwent the examination of corneal tomography, Pentacam HR (Oculus, Wetzlar, Germany). Data of horizontal pachymetric profile passing through the apex of 6 mm was evaluated. With these data, the thickness at the corneal apex (P.ápice), the thickness of the thinnest point of the horizontal profile (P.min.H), the pachymetric progression from the thinnest point to the thickest (PPmin-max), the average pachymetric progression in the meridian as reference the average from the normal population (PPméd) and the fitness with a second degree polynomial trendline (R2). An artificial intelligence model was built to combine this data. The performance for distinguishing normal keratoconus was evaluated by ROC curves. Results: All of these indices were statistically different between the two groups (p <0.001). The area under the ROC curve (AUC) thickness at the apex and TP were 0.904 and 0.938, respectively. The tomographic index with higher AUC was BAD-D (0.997). Regarding the horizontal profile, the AUC of PP.min.H and PPmin-max were 0.915 and 0.927, respectively. The fitness to the trendline to the horizontal thickness graph AUC was 0.896. The best performance was obtained with the PPméd (AUC 0.932 sensitivity = 84.4% and specificity of 92.5%). The artificial intelligence model combining all items derived from horizontal profile improved performance (AUC 0.991 Sensitivity = 96% and specificity of 98%). Conclusion: The horizontal thickness profile can detect keratoconus, with a capacity comparable to more complex indices. This type of analysis can provide the basics for new approaches, using data present in simpler devices than the tomographer reducing the cost for the patients.


Subject(s)
Humans , Adult , Tomography/methods , Corneal Topography/methods , Corneal Pachymetry/methods , Keratoconus/diagnosis , Tomography/instrumentation , Retrospective Studies , Cornea/anatomy & histology , Cornea/diagnostic imaging , Corneal Topography/instrumentation , Corneal Pachymetry/instrumentation
4.
Rev. bras. oftalmol ; 73(2): 75-80, Mar-Apr/2014. tab, graf
Article in English | LILACS | ID: lil-718436

ABSTRACT

Purpose: To compare the ability to detect preoperative ectasia risk among LASIK candidates using classic ERSS (Ectasia Risk Score System) and Pentacam Belin-Ambrósio deviation index (BAD-D), and to test the benefit of a combined approach including BAD-D and clinical data. Methods: A retrospective nonrandomized study involved preoperative LASIK data from 23 post-LASIK ectasia cases and 266 stable-LASIK (follow up > 12 months). Preoperative clinical and Pentacam (Oculus; Wetzlar, Germany) data were obtained from all cases. Mann-Whitney's test was performed to assess differences between groups. Stepwise logistic regression was used for combining parameters.The areas under the Receiver Operating Characteristic (ROC) curves (AUC) were calculated for all parameters and combinations, with pairwise comparisons of AUC (DeLong's method). Results: Statistically significant differences were found for age, residual stromal bed (RSB), central corneal thickness and BAD-D (p<0.001), but not for sphere, cylinder or spherical equivalent (p>0.05). ERSS was 3 or more on 12/23 eyes from the ectasia group (sensitivity = 52.17%) and 48/266 eyes from the stable LASIK group (18% false positive). BAD-D had AUC of 0.931 (95% CI: 0.895 to 0.957), with cut-off of 1.29 (sensitivity = 87%; specificity = 92.1%). Formula combining BAD-D, age and RSB provided 100% sensitivity and 94% specificity, with better AUC (0.989; 95% CI: 0.969 to 0.998) than all individual parameters (p>0.001). Conclusion: BAD-D is more accurate than ERSS. Combining clinical data and BAD-D improved ectasia susceptibility screening. Further validation is necessary. Novel combined functions using other topometric and tomographic parameters should be tested to further enhance accuracy. .


Objetivo: Comparar a capacidade de detectar risco de ectasia no pré-operatório de LASIK usando o clássico ERSS (Ectasia Risk Score System) e índice Belin- Ambrósio (BAD- D) do Pentacam; e para testar o benefício de uma abordagem combinada, incluindo BAD-D e dados clínicos. Métodos: Estudo não randomizado retrospectivo envolveu dados pré-operatórios de LASIK de 23 casos que evoluíram para ectasia pós-LASIK e 266 casos estáveis após LASIK com acompanhamento mínimo de 12 meses. Dados préoperatórios clínicos e do Pentacam (Oculus, Wetzlar, Alemanha) foram obtidos para todos os casos. O teste de Mann-Whitney foi realizado para avaliar as diferenças entre grupos. Regressão logística foi utilizada para combinar parâmetros. As áreas sob as curvas Receiver Operating Characteristic (ROC; AUC) foram calculadas para todos os parâmetros e as combinações. Comparações de pares das AUC foram realizadas com método de DeLong. Resultados: Foram encontradas diferenças estatisticamente significativas para a idade, residual leito estromal (RSB), espessura corneana central e BAD- D (p <0,001), mas não para a grau esférico, cilindro ou equivalente esférico (p > 0,05). ERSS foi de três ou mais em 12/23 olhos do grupo ectasia (sensibilidade = 52,17 %) e 48/ 266 olhos do grupo LASIK estável (18% falso positivo). BAD- D teve AUC de 0,931 (IC 95%: 0,895-0,957), com corte de 1,29 (sensibilidade=87%, especificidade=92,1%). A fórmula que combinou BAD-D, idade e RSB, gerou 100% de sensibilidade e especificidade de 94%, com melhor AUC (0,989, IC 95%: 0,969-0,998) do que todos os parâmetros individuais (p>0,001). Conclusão: BAD-D é mais preciso do que ERSS. Combinações de dados clínicos e os BAD-D melhorou a capacidade de identificação ...


Subject(s)
Humans , Adult , Middle Aged , Aged , Corneal Diseases/diagnosis , Corneal Diseases/etiology , Keratomileusis, Laser In Situ/adverse effects , Diagnostic Techniques, Ophthalmological/standards , Dilatation, Pathologic/diagnosis , Dilatation, Pathologic/etiology , Postoperative Complications/prevention & control , Preoperative Care , Predictive Value of Tests , Retrospective Studies , Risk Factors , ROC Curve , Risk Assessment , Cornea/surgery , Cornea/pathology , Corneal Topography
5.
Rev. bras. oftalmol ; 70(6): 408-410, nov.-dez. 2011. ilus
Article in English | LILACS | ID: lil-612916

ABSTRACT

Different applications of trypan blue (TB) for intraocular surgery have been reported, with very high levels of safety and efficacy. We describe the use of TB as an alternative vital dye for staining the ocular surface to assess the integrity of superficial cell layers of the cornea and the surface environment. This facilitates the diagnosis of various ocular surface disorders, including screening for dry eye disease (DED) among refractive and cataract patients. TB staining properties are different from fluorescein and both are stable in a solution, so that a double staining technique is introduced.


Diferentes aplicações do azul de tripano (AT) foram descritas para cirurgia intraocular, com elevados patamares de eficácia e segurança. Neste relato, é descrito a aplicação do AT como corante vital para superfíce ocular, de modo a estudar a integridade das células da superfície corneana e conjuntival na superfície ocular. Tal abordagem permite um diagnóstico mais sensível de desordens da superfície ocular, destacando-se disfunção lacrimal ou síndrome do olho seco. O AT tem propriedades distintas da fluoresceína, com a qual se mantém estável em solução permitindo a técnica de coloração dupla que é introduzida.


Subject(s)
Humans , Staining and Labeling/methods , Trypan Blue/administration & dosage , Coloring Agents/administration & dosage , Eye Diseases/diagnosis , Ophthalmologic Surgical Procedures , Cohort Studies , Conjunctiva/pathology , Cornea/pathology , Fluorescein/administration & dosage , Slit Lamp Microscopy
6.
Rev. bras. oftalmol ; 70(2): 99-103, mar.-abr. 2011. tab
Article in Portuguese | LILACS | ID: lil-586708

ABSTRACT

OBJETIVO: Avaliar as indicações e os resultados do transplante de córnea em crianças na Fundação Altino Ventura (FAV). MÉTODOS: Foi realizado estudo retrospectivo em 33 pacientes (34 olhos), com idades igual ou inferior a 12 anos, que haviam sido submetidos a transplante penetrante de córnea entre 2000 e 2009 na FAV. A média dos tempos de seguimento pós-operatório foi de 32,5±23,2 meses (variando de 4 meses a 7 anos). Os dados analisados foram: indicação cirúrgica; acuidade visual para longe com melhor correção óptica (AVLc/c) no pré-operatório e na última consulta de seguimento, equivalente esférico refracional (EE) pós-cirurgia e complicações. Os resultados qualitativos foram expressos por suas frequências e os quantitativos por suas médias e desvios padrão. Utilizou-se o teste de t-Student para verificar possível diferença entre médias, aceitando-se o nível de significância de 95,0 por cento (p<0,05). RESULTADOS: A média das idades dos pacientes na cirurgia foi de 7,5 ± 3,3 anos (variando de 2 a 12 anos). Vinte e sete transplantes (79,4 por cento) tiveram indicação óptica e sete (20,6 por cento) tectônica ou terapêutica. A principal indicação entre os ópticos foi leucoma pós-trauma em dezoito (52,9 por cento). A acuidade visual melhorou em 21 (61,7 por cento) olhos e piorou em oito (23,5 por cento). Entre os transplantes ópticos, a rejeição esteve presente em quatro (14,8, por cento) olhos. Em quatro (11,8 por cento) olhos houve desenvolvimento de glaucoma. CONCLUSÃO: Na FAV, o leucoma pós-trauma foi a causa mais frequente de indicação do transplante de córnea em crianças, isto pode ser o resultado da baixa condição sócioeconômica e violência entre a população estudada. Uma proporção significativa de crianças cegas por problemas corneanos obteve melhora funcional da visão através do tratamento cirúrgico apropriado e bom acompanhamento no pós -operatório.


PURPOSE: To evaluate the indications and results after penetrating keratoplasty in children at Altino Ventura Foundation (FAV). METHODS: A retrospective study was performed in 33 patients (34 eyes), with ages equal or less than 12 years, they underwent a penetrating keratoplasty at FAV, from 2000 to 2009. The mean follow up time was 32.5 ± 23.1 months. Surgery indication, best corrected visual acuity (BCVA) before and after surgery, spherical equivalent (SE) pos surgical and complications were analyzed. The qualitative results were expressed by their frequencies and the quantitative by their means and standard deviations. The t-Student test was used to verify possible differences between means. The level of significance was 95.0 percent (p<0.05). RESULTS: Mean age at surgery was 7.5 ± 3.3 years. Twenty seven (79.4 percent) grafts had optical indication and seven (20.6 percent) therapeutic or tectonic. Among the optical transplants, the most frequent indication was cornea opacity after ocular trauma in 18 (52.9 percent) eyes. The visual acuity was better in 21 (61.7 percent) eyes and worse in eight (23.5 percent). In the optical transplants, rejection was present in four (14.8 percent) eyes, and four (11.8 percent) developed glaucoma. CONCLUSION: In FAV opacity after ocular trauma was the most common indication for pediatric keratoplasty. This may be the result of the low income and violent society, among the citizens from the studied population. Many blind children due to cornea disease may achieve improvement in visual acuity if an appropriate surgical and good postoperative management is performed.

SELECTION OF CITATIONS
SEARCH DETAIL